Title: Estimating rain attenuation at THZ frequencies from historical data collected in Brasilia, DF
Authors: Morais, Lucas Vasconcelos de
metadata.dc.contributor.email: lvmorais@gmail.com
Orientador(es):: Menezes, Leonardo Rodrigues Araújo Xavier de
Assunto:: Distribuição das gotas de chuva
Terahertz
Teoria de Mie
Chuvas
Issue Date: 12-Aug-2022
Citation: MORAIS, Lucas Vasconcelos de. Estimating rain attenuation at THZ frequencies from historical data collected in Brasilia, DF. 2022. 53 f., il. Dissertação (Mestrado em Engenharia Elétrica) — Universidade de Brasília, Brasília, 2022.
Abstract: A seguinte dissertação de mestrado propõe um caso de estudo que visa estimar a atenuação causada pela chuva no espectro em Terahertz. Usando dados da chuva coletados durante 20 anos em Brasília, DF, Brasil pelo Instituto Nacional de Meteorologia (INMET) foi possível realizar uma estimativa da atenuação média causada pela chuva. Norteado por um processo estatístico que usa como base a teoria de Monte Carlo e também a Transformada da Incerteza foi possível obter uma razoável estimativa teórica do impacto das chuvas em Brasília no contexto da comunicação em THz. Para calcular valores médios de atenuação usamos a Teoria de Mie em conjunto com a distribuição de Weibull e em seguida comparamos com resultados clássicos obtidos pela norma da ITU-R. A estimativa proposta por esse trabalho mostra que a atenuação média varia entre 1,91 dB/km e 2,66 dB/km. Para eventos de chuvas com taxas acima de 10 mm/hr, nossos resultados demonstraram que a atenuação média varia entre 8,56 e 15,96 dB/km.
Abstract: This work proposes a case study for estimating rain attenuation with rainfall data collected in Brasilia, Brazil at THz frequencies using Mie Theory and Drop Size Distribution. To address this goal, we used measured rainfall rate data for the past 20 years collected at the National Institute of Meteorology (INMET). A statistical approach that uses Monte Carlo simulation was applied to obtain a reasonable estimation of rainfall attenuation in the Terahertz spectrum. To evaluate the method’s accuracy, we performed a comparison between the rain attenuation calculated by Mie Theory and ITU-R model. The estimation proposed in this work showed that the mean attenuation varies between 1.91 to 2.66 dB/km. For rain events greater than 10 mm/h, results showed that the mean attenuation varies between 8.56 to 15.96 dB/km.
metadata.dc.description.unidade: Faculdade de Tecnologia (FT)
Departamento de Engenharia Elétrica (FT ENE)
Description: Dissertação (mestrado) — Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Elétrica, 2022.
metadata.dc.description.ppg: Programa de Pós-Graduação em Engenharia Elétrica
Licença:: A concessão da licença deste item refere-se ao termo de autorização impresso assinado pelo autor com as seguintes condições: Na qualidade de titular dos direitos de autor da publicação, autorizo a Universidade de Brasília e o IBICT a disponibilizar por meio dos sites www.bce.unb.br, www.ibict.br, http://hercules.vtls.com/cgi-bin/ndltd/chameleon?lng=pt&skin=ndltd sem ressarcimento dos direitos autorais, de acordo com a Lei nº 9610/98, o texto integral da obra disponibilizada, conforme permissões assinaladas, para fins de leitura, impressão e/ou download, a título de divulgação da produção científica brasileira, a partir desta data.