Skip navigation
Please use this identifier to cite or link to this item: http://repositorio.unb.br/handle/10482/48928
Files in This Item:
File SizeFormat 
WilamyValadaresDeCastro_DISSERT.pdf2,56 MBAdobe PDFView/Open
Title: Análise de sensibilidade à degradação das zonas de fachadas com revestimento cerâmico
Authors: Castro, Wilamy Valadares de
Orientador(es):: Souza, Jessica Siqueira de
Coorientador(es):: Matos, Ana Filipa Ferreira da Silva Cigarro
Assunto:: Fachadas de edificações
Revestimento cerâmico
Revestimento cerâmicoDegradação da estrutura
Issue Date: 16-Jul-2024
Citation: CASTRO, Wilamy Valadares de. Análise de sensibilidade à degradação das zonas de fachadas com revestimento cerâmico. 2023. xiii, 75 f., il. Dissertação (Mestrado em Estruturas e Construção Civil) — Universidade de Brasília, Brasília, 2023.
Abstract: As fachadas com revestimentos cerâmicos são muito usadas devido a este tipo de revestimento proporcionar maior proteção à edificação quando comparada as demais opções de mercado. Entretanto placas cerâmicas em fachadas não são imunes às anomalias. Este estudo propõe esquemas gráficos que identificam a suscetibilidade às anomalias em cada zona da fachada para edifícios com revestimento cerâmico, analisando os níveis de degradação. A base de dados considera mais de 300 trechos de fachadas de edifícios residenciais em Brasília, Brasil. A área de estudo é aproximadamente 81.500 m², em que foi identificado as anomalias descolamento cerâmico, fissuras, falha de rejunte e eflorescência. O Método de Mensuração de Degradação (MMD) foi aplicado para o cálculo da probabilidade e sensibilidade de ocorrência das anomalias nas zonas de fachadas e posteriormente ponderou as anomalias entre si com o objetivo de hierarquizar por grau de importância das anomalias para as fachadas com revestimento cerâmico. Os resultados revelam que o descolamento é a anomalia mais frequente destacando maior gravidade. Os mapas de sensibilidade propostos permitem identificar um padrão na ocorrência de danos em revestimentos cerâmicos, revelando que as zonas de paredes contínuas, transição entre pavimentos e topo do edifício são áreas vulneráveis a anomalias. Em contra partida, as sacadas têm menor sensibilidade à presença de anomalias. Os mapas trazem informações que podem ser utilizadas para melhores decisões de concepção e construção no início do ciclo de vida dos edifícios, ajudando a prevenir e mitigar a ocorrência de danos, como também auxilia na detecção e elaboração do diagnóstico da condição de degradação atual da fachada.
Abstract: Facades with ceramic cladding are widely used because this type of coating provides greater protection to the building when compared to other market options. However, ceramic tiles on facades are not immune to anomalies. This study proposes graphic schemes that identify the susceptibility to anomalies in each zone of the facade for buildings with ceramic coating, analyzing the levels of degradation. The database considers more than 300 sections of facades of residential buildings in Brasília, Brazil. The study area is approximately 81,500 m², in which the anomalies of ceramic detachment, cracks, grout failure and efflorescence were identified. The Degradation Measurement Method (MMD) was applied to calculate the probability and sensitivity of the occurrence of anomalies in the façade zones and subsequently weighted the anomalies against each other in order to rank the anomalies by degree of importance for the façades with ceramic coating. The results reveal that detachment is the most frequent anomaly, highlighting greater severity. The proposed sensitivity maps make it possible to identify a pattern in the occurrence of damage to ceramic tiles, revealing that the areas of Continuous Walls, Transition between Floors and Top of the building are areas vulnerable to anomalies. On the other hand, balconies are less sensitive to the presence of anomalies. The maps bring information that can be used for better design and construction decisions at the beginning of the life cycle of buildings, helping to prevent and mitigate the occurrence of damage, as well as assisting in the detection and elaboration of the diagnosis of the current degradation condition of the façade.
metadata.dc.description.unidade: Faculdade de Tecnologia (FT)
Departamento de Engenharia Civil e Ambiental (FT ENC)
Description: Dissertação (mestrado) — Universidade de Brasília, Programa de Pós-Graduação em Estruturas e Construção Civil, Faculdade de Tecnologia, 2023.
metadata.dc.description.ppg: Programa de Pós-Graduação em Estruturas e Construção Civil
Licença:: A concessão da licença deste item refere-se ao termo de autorização impresso assinado pelo autor com as seguintes condições: Na qualidade de titular dos direitos de autor da publicação, autorizo a Universidade de Brasília e o IBICT a disponibilizar por meio dos sites www.unb.br, www.ibict.br, www.ndltd.org sem ressarcimento dos direitos autorais, de acordo com a Lei nº 9610/98, o texto integral da obra supracitada, conforme permissões assinaladas, para fins de leitura, impressão e/ou download, a título de divulgação da produção científica brasileira, a partir desta data.
Agência financiadora: Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq).
Appears in Collections:Teses, dissertações e produtos pós-doutorado

Show full item record " class="statisticsLink btn btn-primary" href="/jspui/handle/10482/48928/statistics">



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.