Skip navigation
Veuillez utiliser cette adresse pour citer ce document : http://repositorio.unb.br/handle/10482/47692
Fichier(s) constituant ce document :
Fichier Description TailleFormat 
ARTIGO_ExperimentalInvestigationAxially.pdf14,56 MBAdobe PDFVoir/Ouvrir
Titre: Experimental investigation of axially loaded precast sandwich panels
Auteur(s): Ribeiro, Kamirã Barbosa
Silva, William Taylor Matias
Silva, Ramon Saleno Yure Rubim Costa
Silva, Welington Vital da
Bezerra, Luciano Mendes
metadata.dc.identifier.orcid: https://orcid.org/0009-0002-8572-0121
https://orcid.org/0000-0002-8806-0440
https://orcid.org/0000-0003-2004-6236
https://orcid.org/0000-0001-5200-5995
metadata.dc.contributor.affiliation: University of Brasilia, Department of Civil and Environmental Engineering
University of Brasilia, Department of Civil and Environmental Engineering
University of Brasilia, Department of Civil and Environmental Engineering
University of Brasilia, Department of Civil and Environmental Engineering
University of Brasilia, Department of Civil and Environmental Engineering
Assunto:: Painel sanduíche pré-moldado
Testes
Date de publication: 4-aoû-2023
Editeur: MDPI
Référence bibliographique: BARBOSA, Kamurâ et al. Experimental investigation of axially loaded precast sandwich panels. Buildings, [S. l.], v. 13, n. 8, 1993, 2023. DOI: https://doi.org/10.3390/buildings13081993. Disponível em: https://www.mdpi.com/2075-5309/13/8/1993. Acesso em: 06 fev. 2024.
Abstract: This paper reports the results of three thin wythe precast sandwich panels tested under axial load. Panel reinforcements and shear connectors in the current state of precast sandwich panels in the civil construction context are evaluated. The authors measured displacement at two distinct panel heights as well as along the panel width to provide load–displacement behavior at the cross-section level and broaden the experimental data on the subject. The test results developed in this research showed good agreement with the results available in the literature. In addition, as concrete-wall panel strength equations have been linked to the compressive behavior of precast sandwich panels, a brief review of empirical formulae is also offered in this paper. Moreover, empirical data since 2005, on both concentrical and eccentrical load testing available in the literature, are also reported.
metadata.dc.description.unidade: Faculdade de Tecnologia (FT)
Departamento de Engenharia Civil e Ambiental (FT ENC)
metadata.dc.description.ppg: Programa de Pós-Graduação em Estruturas e Construção Civil
Licença:: Copyright: © 2023 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https:// creativecommons.org/licenses/by/ 4.0/).
DOI: https://doi.org/10.3390/buildings13081993
Collection(s) :Artigos publicados em periódicos e afins

Affichage détaillé " class="statisticsLink btn btn-primary" href="/jspui/handle/10482/47692/statistics">