Skip navigation
Please use this identifier to cite or link to this item: http://repositorio.unb.br/handle/10482/40546
Files in This Item:
File Description SizeFormat 
2020_MariadosReisSantosBorges.pdf27,79 MBAdobe PDFView/Open
Title: Utilização de placas microperfuradas em filtros acústicos do tipo câmara de expansão para controle de ruído em dutos
Authors: Borges, Maria dos Reis Santos
Orientador(es):: Nunes, Maria Alzira de Araújo
Assunto:: Filtros acústicos reativos
Placa microperfurada
Câmara de expansão
Perda de transmissão
Issue Date: 14-Apr-2021
Citation: BORGES, Maria dos Reis Santos.Utilização de Placas Microperfuradas em Filtros Acústicos do tipo Câmara de Expansão para Controle de Ruído em Dutos. 2020. xviii, 115 f., il. Dissertação (Mestrado em Integridade de Materiais da Engenharia)—Universidade de Brasília, Brasília, 2020.
Abstract: Os filtros acústicos reativos são silenciadores cujo mecanismo de atenuação sonora está associado às descontinuidades geométricas existentes em seu interior, que adicionam mudanças de impedância às ondas sonoras incidentes. Na prática, esses atenuadores, em sua maioria, destinam-se ao controle de ruído passivo em dutos de exaustão de grandes máquinas. Isso se deve ao fato de que tais atenuadores são mais eficientes em baixas frequências, região na qual ruído de exaustão possui maior amplitude. Em grupos geradores de energia, o filtro acústico reativo mais utilizado é o do tipo câmara de expansão, que consiste em súbitas expansões e contrações de área. Esse tipo de silenciador dispensa a aplicação de materiais porosos ou fibrosos, evitando a poluição do ar circundante causada pela degradação desses materiais. Neste trabalho são propostos 12 modelos de câmaras de expansão com placa microperfurada (Microperforated Panel - MPP) em seu interior, afim de que este seja uma alternativa viável no controle passivo do ruído de exaustão. Com o objetivo principal de estimar a perda de transmissão (Transmission Loss - TL) dos filtros acústicos propostos, primeiro a mesma foi obtida analiticamente, através do Método da Matriz de Transferência (MMT), utilizando o modelo de câmara de expansão simples como referência. Em seguida, foi desenvolvido um modelo numérico via Método dos Elementos Finitos (MEF) no software . Com a validação entre as duas técnicas de obtenção, foi construída uma bancada experimental que proporciona a determinação da TL via Método de Duas Cargas. Com isso, o comportamento dos atenuadores foi analisado e comparado de maneira experimental, fornecendo não só uma estimativa mais próxima da realidade, como diretrizes para aumentar e prever as amplitudes máximas de TL, de acordo com a inserção da MPP e das complexidades geométricas inseridas
Abstract: The reactive acoustic filters are type of silencers whose sound attenuation mechanism is the geometric discontinuities, which add impedance changes to the incident sound waves. In practice, these attenuators, for the most part, are designed to passive noise control in exhaust ducts, of large machines. This is due to that such silencers are more efficient at low frequencies, a region where the exhaust noise has greater amplitude. In energy generating groups, the most used reactive acoustic filter is the expansion chamber type, which consists of sudden expansions and contractions of the area. This type of silencer dispenses with the application of porous or fibrous materials, preventing pollution of the surrounding air caused by the degradation of these materials. In this work, 12 models of expansion chambers with microperforated panel (MPP) are proposed in their interior, in order that, this is a viable alternative in passive control of exhaust noise. With the main objective of estimating the Transmission Loss (TL) of the proposed acoustic filters, first it was obtained analytically, using the Transfer Matrix Method (TMM), using the simple expansion chamber model as a reference. Then, a numerical model was developed via Finite Element Method (FEM) in software . With the validation between these two obtaining techniques, an experimental bench was built, that provides the determination of TL via the Two Load Method. With this, the behavior of the attenuators was analyzed and compared in an experimental way, providing not only an estimate closer to reality, but guidelines for increasing and predicting the maximum amplitudes of TL, according to the insertion of the MPP and the geometric complexities.
Description: Dissertação (mestrado)—Universidade de Brasília, Faculdade UnB Gama, Programa de Pós-Graduação em Integridade de Materiais da Engenharia, 2020.
Licença:: A concessão da licença deste item refere-se ao termo de autorização impresso assinado pelo autor com as seguintes condições: Na qualidade de titular dos direitos de autor da publicação, autorizo a Universidade de Brasília e o IBICT a disponibilizar por meio dos sites www.bce.unb.br, www.ibict.br, http://hercules.vtls.com/cgi-bin/ndltd/chameleon?lng=pt&skin=ndltd sem ressarcimento dos direitos autorais, de acordo com a Lei nº 9610/98, o texto integral da obra disponibilizada, conforme permissões assinaladas, para fins de leitura, impressão e/ou download, a título de divulgação da produção científica brasileira, a partir desta data.
Appears in Collections:Teses, dissertações e produtos pós-doutorado

Show full item record " class="statisticsLink btn btn-primary" href="/jspui/handle/10482/40546/statistics">



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.