Skip navigation
Use este identificador para citar ou linkar para este item: http://repositorio.unb.br/handle/10482/39016
Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
2020_JohnKennedyFonsecaSilva.pdf4,48 MBAdobe PDFVisualizar/Abrir
Título: Avaliação experimental sobre o comportamento mecânico de conectores de cisalhamento do tipo Perfofrp em paredes pré-moldadas de concreto com isolamento incorporado
Autor(es): Silva, John Kennedy Fonsêca
Orientador(es): Lameiras, Rodrigo de Melo
Assunto: Polímeros
Concreto armado
Conectores
Estruturas de concreto
Cisalhamento
Data de publicação: 6-Jul-2020
Referência: SILVA, John Kennedy Fonsêca. Avaliação experimental sobre o comportamento mecânico de conectores de cisalhamento do tipo Perfofrp em paredes pré-moldadas de concreto com isolamento incorporado. 2020. 80 f., il. Dissertação (Mestrado em Estruturas e Construção Civil) — Universidade de Brasília, Brasília, 2020.
Resumo: As paredes pré-moldadas de concreto com isolamento incorporado (painéis sanduíche) consistem em duas camadas externas de concreto unidas por um conector, entre as quais, encontra-se inserida uma camada interna de material isolante, com o objetivo de melhorar a sua performance térmica e acústica. Uma das grandes preocupações no que diz respeito ao desempenho desses painéis, refere-se à eliminação das pontes térmicas ocasionadas pelas conectores metálicos, que minam a sua eficiência energética. Uma das proposições para sanar parte desse problema consiste no emprego dos conectores Perfofrp, que são chapas planas perfuradas fabricadas com polímero reforçado com fibra de vidro (PRFV), confeccionados com um determinado número de furos por onde o concreto passa criando pinos de ancoragem, que promovem resistência ao cisalhamento e à separação das paredes de concreto. Objetivou-se, com esta pesquisa, detalhar e avaliar a fabricação desse tipo de conexão, empregando-se um sistema de produção de baixo custo. Além disso, após a fabricação das conexões, 46 espécimes confeccionados com a conexão citada foram submetidos ao ensaio push-out, com o objetivo de avaliar o desempenho mecânico da conexão mencionada. Os resultados apontaram para uma qualidade de produção com um nível de variação das características do compósito satisfatória, considerando: a variabilidade do compósito produzido, a variabilidade entre chapas oriundas de diferentes infusões, e a variabilidade entre lotes de produção. Além disso, os ensaios push-out demonstraram que as conexões constituídas por furos apresentaram, quando comparadas com as conexões sem perfurações: um ganho de resistência variando entre -6 % e 45 %, deslocamentos relativos menos elevados, além de maiores níveis de rigidez.
Abstract: Insulated pre-cast concrete wall panels, also called sandwich panels, consist in two external concrete layers, in which an internal layer of thermal insulation material is inserted between, aiming better acoustic and thermal performance. One of the main concerns regarding the performance of these panels refers to the elimination of thermal bridges caused by metallic connectors, which jeopardize the panels’ thermal efficiency. One of the proposals to solve this problem consists in the use of Perfofrp connectors, which are plane plates with perforated holes through its thickness, which are embedded into the concrete plates, creating anchorage pins that enhance the shear strength and the layers’ debonding resistance. This research had the objective of evaluating the production quality of this type of connector, produced with a low-cost vacuum assisted resin infusion system. Also, 46 specimens, in the form of representative models of the shear connector in insulated pre-cast concrete wall panels, were subjected to push-out tests, in order to assess the mechanical performance of the connector. The results indicated a production quality with a satisfactory level of characteristics variation, considering: the variability in different parts of a single composite plate, the variability between composite plates from different infusion process, and the variability between different production batches. Furthermore, the push-out tests demonstrated that the perforated connectors presented, when compared to non-perforated connectors: a gain in shear strength from -6% to 45%, lower relative displacements, and higher levels of stiffness
Unidade Acadêmica: Faculdade de Tecnologia (FT)
Departamento de Engenharia Civil e Ambiental (FT ENC)
Informações adicionais: Dissertação (mestrado) — Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Civil, 2020.
Programa de pós-graduação: Programa de Pós-Graduação em Estruturas e Construção Civil
Licença: A concessão da licença deste item refere-se ao termo de autorização impresso assinado pelo autor com as seguintes condições: Na qualidade de titular dos direitos de autor da publicação, autorizo a Universidade de Brasília e o IBICT a disponibilizar por meio dos sites www.bce.unb.br, www.ibict.br, http://hercules.vtls.com/cgi-bin/ndltd/chameleon?lng=pt&skin=ndltd sem ressarcimento dos direitos autorais, de acordo com a Lei nº 9610/98, o texto integral da obra disponibilizada, conforme permissões assinaladas, para fins de leitura, impressão e/ou download, a título de divulgação da produção científica brasileira, a partir desta data.
Agência financiadora: CAPES
Aparece nas coleções:Teses, dissertações e produtos pós-doutorado

Mostrar registro completo do item Visualizar estatísticas



Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.