Skip navigation
Por favor, use este identificador para citar o enlazar este ítem: http://repositorio2.unb.br/jspui/handle/10482/31296
Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
2017_AmaroEduardoTavaresdeAraújo.pdf1,13 MBAdobe PDFVisualizar/Abrir
Título : Confiabilidade e concordância intra e interexaminadores do teste de eletrodiagnóstico de estímulo em pacientes sedados sob cuidados intensivos
Autor : Araujo, Amaro Eduardo Tavares de
Orientador(es):: Durigan, João Luiz Quagliotti
Assunto:: Eletrodiagnóstico
Fisioterapia
Sistema musculoesquelético
Teste de desempenho
Fecha de publicación : 26-feb-2018
Citación : ARAUJO, Amaro Eduardo Tavares de. Confiabilidade e concordância intra e interexaminadores do teste de eletrodiagnóstico de estímulo em pacientes sedados sob cuidados intensivos. 2017. 41 f., il. Dissertação (Mestrado em Educação Física)—Universidade de Brasília, Brasília, 2017.
Resumen : Introdução: A restrição no leito, causa várias complicações que podem levar a desordens eletrofisiológicos neuromusculares (DEN). O teste de eletrodiagnóstico de estímulo (TEDE) é uma ferramenta utilizada pelo fisioterapeuta para diagnosticar DEN, embora as propriedades psicométricas do TEDE ainda não tenham sido descritas. Objetivo: Verificar a confiabilidade e concordância intra e interexaminadores do TEDE das medidas obtidas por eletrodos caneta (0,78 cm2) e quadrado (25 cm2) nos músculos vasto lateral (VL) e tibial anterior (TA). Método: Foi realizado um estudo observacional de corte transversal com 30 pacientes criticamente enfermos para avaliar a cronaxia mensurada por dois examinadores independentes para diagnosticar DEN, com diferentes eletrodos e músculos. Resultado: Excelente confiabilidade foi observada para a analise intraexaminador. Concordâncias absolutas foram obtidas para o músculo VL. Nenhuma diferença foi encontrada entre os eletrodos. Conclusão: TEDE apresenta resultados confiáveis e reprodutíveis nas avaliações intra examinador. Testes realizados com diferentes tipos de eletrodos não influenciaram os resultados. TEDE pode ser realizado com eletrodos quadrados (25 cm2 de área), o que pode aumentar sua viabilidade na prática clínica.
Abstract: Introduction: The bed restriction causes several complications that can lead to neuromuscular electrophysiological disorders (NED). The stimulus electrodiagnosis test (SET) is a tool widely used by the physiotherapist to diagnose NED, although the psychometric properties of the SET have not yet been described. Objective: To verify the intra and interrater reliability and agreement of the SET of measurements obtained by different electrodes (pen - area of 0.78 cm2 and square - area of 25 cm2) in the vastus lateralis (VL) and tibialis anterior (TA) muscles. Method: A cross-sectional, observational study was performed with 30 critically ill patients through chronaxie, measured by two independent raters for the diagnosis of NED, with different electrodes and muscles. Result: Excellent reliability was observed for intra-rater analysis. Absolute agreement was obtained for the VL muscle. No difference was found in the type of electrode. Conclusion: SET presents reliable and reproducible results in intra-rater evaluations. Tests performed with different types of electrodes did not influence the results. SET can be performed with square electrodes (25 cm2 area), which may increase the viability of this test in clinical practice.
metadata.dc.description.unidade: Faculdade de Educação Física (FEF)
Descripción : Dissertação (mestrado)—Universidade de Brasília, Faculdade de Educação Física, Programa de Pós-Graduação em Educação Física, 2017.
metadata.dc.description.ppg: Programa de Pós-Graduação em Educação Física
Licença:: A concessão da licença deste item refere-se ao termo de autorização impresso assinado pelo autor com as seguintes condições: Na qualidade de titular dos direitos de autor da publicação, autorizo a Universidade de Brasília e o IBICT a disponibilizar por meio dos sites www.bce.unb.br, www.ibict.br, http://hercules.vtls.com/cgi-bin/ndltd/chameleon?lng=pt&skin=ndltd sem ressarcimento dos direitos autorais, de acordo com a Lei nº 9610/98, o texto integral da obra disponibilizada, conforme permissões assinaladas, para fins de leitura, impressão e/ou download, a título de divulgação da produção científica brasileira, a partir desta data.
Aparece en las colecciones: Teses, dissertações e produtos pós-doutorado

Mostrar el registro Dublin Core completo del ítem " class="statisticsLink btn btn-primary" href="/jspui/handle/10482/31296/statistics">



Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.