Skip navigation
Por favor, use este identificador para citar o enlazar este ítem: http://repositorio.unb.br/handle/10482/27005
Ficheros en este ítem:
Fichero Tamaño Formato  
ARTIGO_TesteBiocompatibilidadeResistencia.pdf154,81 kBAdobe PDFVisualizar/Abrir
Título : Teste de biocompatibilidade e resistência de membranas de látex em cães
Biocompatibility and resistance test of latex membranes in dogs
Autor : Zimmermann, Marina
Raiser, Alceu Gaspar
Barbosa, Anna Laetícia da Trindade
Novosad, Deisi
Steffen, Renata Pamela Barrachi
Lukarsewsk, Rafael
Silva, Marcelo Soares da
Lindinger, Renato
Pastore Junior, Floriano
Assunto:: Látex
Biocompatibilidade
Cão
Fecha de publicación : 2007
Editorial : Universidade Federal de Santa Maria
Citación : ZIMMERMANN, Marina et al. Teste de biocompatibilidade e resistência de membranas de látex em cães. Ciência Rural, Santa Maria, v. 37, n. 6, p. 1719-1723, dez. 2007. doi: http://dx.doi.org/10.1590/S0103-84782007000600033. Disponível em: http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0103-84782007000600033&lng=pt&nrm=iso. Acesso em: 19 set. 2019.
Resumen : O látex natural extraído da seringueira (Hevea brasiliensis) possui propriedades indutoras de neovascularização e regeneração tecidual, comprovadas em várias espécies e em diferentes tecidos do organismo. Este estudo testou a biocompatibilidade e a resistência de três membranas de látex em seis cadelas, sendo duas dessas membranas ainda não utilizadas e uma já testada em estudos prévios. Os implantes foram colocados entre os músculos cutâneo e reto do abdome através de procedimento cirúrgico e, após 45 dias, foram removidos e submetidos a exames histológicos. Durante esse período, os animais foram avaliados quanto à dor e às alterações clínicas e macroscópicas nas membranas. Testes mecânicos de tração para determinação de deformação e resistência foram efetuados em amostras-controle. Pelos resultados obtidos, concluiu-se que as membranas testadas são compatíveis para substituir a bainha muscular em cães, exceto a membrana 2, por apresentar características de rejeição.
Abstract: The natural latex extracted of the Rubber Tree, has properties to induce characteristics of tissue vascularization and regeneration that had been comproved in different species and tissues. This study tested the biocompatibility of three latex membranes in six dogs. Two of these membranes have not been used yet, while one of them has been tested in previous studies. Membranes were implanted between the cutaneous and the rectum of the abdomen muscles by a surgical procedure. In a forty five days period, the animals were evaluated for pain, clinical and macroscopic alterations of the membranes and, after the membranes were removed in order to submit them to histological exams. Mechanical traction tests were realized in control membranes to measure deformation and resistance. The results indicated that membranes are compatible, and able to substitute the muscular sheath in dogs, excepting membrane 2, because of it rejecting characteristics.
metadata.dc.description.unidade: Instituto de Química (IQ)
Licença:: Ciência Rural - (CC BY NC) - Todo o conteúdo deste periódico, exceto onde está identificado, está licenciado sob uma Licença Creative Commons. Fonte: http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0103-84782007000600033&lng=pt&tlng=pt. Acesso em: 19 set. 2019.
DOI: https://dx.doi.org/10.1590/S0103-84782007000600033
Aparece en las colecciones: Artigos publicados em periódicos e afins

Mostrar el registro Dublin Core completo del ítem " class="statisticsLink btn btn-primary" href="/jspui/handle/10482/27005/statistics">



Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.