Skip navigation
Use este identificador para citar ou linkar para este item: http://repositorio.unb.br/handle/10482/7068
Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
ARTIGO_InfluenciaSistemasRefrigeração.pdf345,52 kBAdobe PDFVisualizar/Abrir
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorLima, Ligia Freitas de-
dc.contributor.authorMoura, Priscilla-
dc.contributor.authorPassos, Pedro Ivo Braga-
dc.contributor.authorLeal, Diogo Ramos-
dc.contributor.authorRumpf, Rodolfo-
dc.contributor.authorNeves, Jairo Pereira-
dc.date.accessioned2011-03-11T17:44:01Z-
dc.date.available2011-03-11T17:44:01Z-
dc.date.issued2010-
dc.identifier.citationLIMA, Ligia Freitas de et al. Influência de sistemas de refrigeração sobre a qualidade do sêmen ovino criopreservado em palhetas. Ciência animal brasileira, Goiânia, v. 11, n. 4, p. 835-844, out./dez. 2010. Disponível em: <http://www.revistas.ufg.br/index.php/vet/article/view/4252/8357>. Acesso em: 08 fev. 2011. Doi: 10.5216/cab.v11i4.4252.en
dc.identifier.urihttp://repositorio.unb.br/handle/10482/7068-
dc.description.abstractAvaliaram-se diferentes sistemas de refrigeração do sêmen ovino, através da aferição e comparação das curvas obtidas e seus efeitos sobre a qualidade do sêmen criopreservado. Ao final da refrigeração, os parâmetros espermáticos motilidade, vigor, defeitos morfológicos, viabilidade e estado acrossomal foram analisados. Para a avaliação pós-descongelação mais dois testes foram acrescentados: avaliação da integridade de membrana plasmática (IMP) e teste de exaustão com quatro horas de incubação a +37ºC. A refrigeração foi realizada em refrigerador doméstico e num balcão horizontal. Para controlar a queda de temperatura desses equipamentos, colocaram-se as palhetas entre bolsas plásticas contendo água aquecida a +32ºC, constituindo quatro sistemas: RS (refrigerador sem bolsa), RC (refrigerador com bolsa), BS (balcão sem bolsa) e BC (balcão com bolsa), os quais resultaram em quatro taxas de refrigeração: -1,4ºC/min, -0,4ºC/min, -2,9ºC/ min e -0,45ºC/min, para RS, RC, BS e BC, respectivamente. Após a refrigeração, observou-se diferença na motilidade espermática (P<0,05), em que BS apresentou menor média. O sistema BS obteve a menor média de vivos íntegros e também a maior de mortos íntegros ao final da refrigeração, diferindo de RC e BC. Quanto aos defeitos morfológicos pós-refrigeração, BS apresentou maior média (P<0,05), ao passo que RC e BC apresentaram as menores médias. Não foram observadas diferenças significativas entre os tratamentos na descongelação e ao final do teste de exaustão. Concluiu-se que as diferentes taxas de refrigeração afetaram o sêmen no final da fase de refrigeração, mas não após a descongelação. __________________________________________________________________________________________ ABSTRACTen
dc.description.abstractDifferent types of cooling systems of ram semen were evaluated by the measurement and comparison of cooling rates and their effects on the post-thawing quality. Motility, vigor, morphology damages, viability and acrosomal status were tested at the end of 90 minutes of cooling and post-thawing. Regarding post-thawed semen, the same parameters were used, in addition to the assessment of the integrity of the plasmatic membrane, and the resistance test by the incubation of semen at +37ºC for 4 hours. Semen refrigeration was carried out in a domestic refrigerator and in a horizontal refrigerator. To control the temperature drop of semen in both equipments, the slats were disposed between plastic bags containing water at +32ºC, constituting four combinations of cooling procedures: RS (refrigerator without bag), RC (refrigerator with bag), BS (horizontal refrigerator without bag) and BC (horizontal refrigerator with bag), resulting in four cooling rates: -1.4ºC/min, -0.4ºC/min, -2.9°C/min and -0.45ºC/min, for RS, RC, BS and BC, respectively. At the end of the cooling period, BS treatment showed the lowest percentage of sperm motility (P<0.05), the lowest mean of live spermatozoa with intact acrosome, and the highest mean of dead spermatozoa with intact acrosome (P<0.05). As for morphological defects, BS treatment had the highest mean whereas the systems RC and BC resulted in the lowest means. There was no significant difference among treatments in relation to frozen-thawed semen at the end of the resistant test. It was concluded that the different cooling rates affected ram semen at the end of cooling stage but not at post-thawing.en
dc.language.isoPortuguêsen
dc.rightsAcesso Abertoen
dc.titleInfluência de sistemas de refrigeração sobre a qualidade do sêmen ovino criopreservado em palhetasen
dc.title.alternativeInfluence cooling systems the quality of ovine semen cryopreserved in strawsen
dc.typeArtigoen
dc.subject.keywordOvinoen
dc.subject.keywordSêmen congeladoen
dc.identifier.doihttps://dx.doi.org/10.5216/cab.v11i4.4252en
dc.description.unidadeFaculdade de Agronomia e Medicina Veterinária (FAV)-
Aparece nas coleções:Artigos publicados em periódicos e afins

Mostrar registro simples do item Visualizar estatísticas



Este item está licenciada sob uma Licença Creative Commons Creative Commons