Skip navigation
Use este identificador para citar ou linkar para este item: http://repositorio2.unb.br/jspui/handle/10482/48069
Arquivos associados a este item:
Não existem arquivos associados a este item.
Título: The performance of the acoustic voice quality index and acoustic breathiness index in synthesized voices
Autor(es): Latoszek, Ben Barsties v.
Englert, Marina
Lucero, Jorge Carlos
Behlau, Mara
Afiliação do autor: Speech-Language Pathology, SRH University of Applied Health Sciences, Düsseldorf, Germany
Department of Phoniatrics and Pediatric Audiology, University Hospital Münster, University of Münster, Münster, Germany
Human Communication Disorders, Universidade Federal de São Paulo -UNIFESP, São Paulo, Sao Paulo, Brazil
Centro de Estudos da Voz - CEV, São Paulo ,SP, Brazil
Department of Computer Science, Universidade de Brasília - UnB, Brasília, Federal District, Brazil
Human Communication Disorders, Universidade Federal de São Paulo -UNIFESP, São Paulo, Sao Paulo, Brazil
Centro de Estudos da Voz - CEV, São Paulo ,SP, Brazil
Assunto: Qualidade vocal
Acústica da voz
Processamento de sinais
Data de publicação: 2023
Editora: Elsevier Inc..
Referência: LATOSZEK, Ben Barsties v.et al. The performance of the acoustic voice quality index and acoustic breathiness index in synthesized voices. Journal of Voice, [S. l.], v. 37, n. 5, p. 804.e21-804.e28, set. 2023. DOI: https://doi.org/10.1016/j.jvoice.2021.05.005.
Abstract: Summary: Objective. The aim of the present study was to investigate the performance of the Acoustic Voice Quality Index (AVQI) and the Acoustic Breathiness Index (ABI) in synthesized voice samples. Method. The validity of the AVQI and ABI performances was analyzed in synthesized voice samples control ling the degree of predefined deviations for overall voice quality (G-scale) and breathiness (B-scale). A range of 26 synthesized voice samples with various severity degrees in G-scale with and without prominence of breathiness for male and female voices were created. Results. ABI received higher validity in the evaluation of breathiness than AVQI. Furthermore, ABI evaluated accurately breathiness degrees without considering roughness effects in voice samples and confirmed the findings of other studies with natural voices. Furthermore, ABI was more robust than AVQI in the evaluation of severe voice-disordered voice samples. Finally, AVQI represented moreover overall voice quality with an emphasis of breathiness evaluation and less roughness although roughness had a necessary component in overall voice quality evaluation. Conclusion. AVQI and ABI are two robust measurements in the evaluation of voice quality. However, ABI received fewer errors than AVQI in the analyses of higher abnormalities in the voice signal. Disturbances of other subtypes of abnormal overall voice quality such as roughness were not demonstrated in the results of ABI.
Unidade Acadêmica: Instituto de Ciências Exatas (IE)
Departamento de Ciência da Computação (IE CIC)
DOI: https://doi.org/10.1016/j.jvoice.2021.05.005
Versão da editora: https://www.sciencedirect.com/science/article/pii/S0892199721001715?via%3Dihub
Aparece nas coleções:Artigos publicados em periódicos e afins

Mostrar registro completo do item Visualizar estatísticas



Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.