Skip navigation
Use este identificador para citar ou linkar para este item: http://repositorio.unb.br/handle/10482/46662
Arquivos associados a este item:
Não existem arquivos associados a este item.
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorTeles, Camila Correia-
dc.contributor.authorGóes, Thiago Montenegro-
dc.contributor.authorLopes, Adriano Felipe Oliveira-
dc.contributor.authorFernandes, Júlia Teixeira-
dc.contributor.authorAmorim, Cláudia Naves David-
dc.contributor.authorSilva, Caio Frederico e-
dc.date.accessioned2023-10-11T12:36:23Z-
dc.date.available2023-10-11T12:36:23Z-
dc.date.issued2019-09-
dc.identifier.citationTELES, Camila Correia et al. Avaliação de eficiência energética e conforto térmico de projetos educacionais padronizados do FNDE. In: ENCONTRO NACIONAL DE CONFORTO NO AMBIENTE CONSTRUÍDO, 15., e ENCONTRO LATINO-AMERICANO DE CONFORTO NO AMBIENTE CONSTRUÍDO, 11., João Pessoa, 2019. Anais […]. Porto Alegre: ANTAC, 2019. p. 2246-2255. Tema: Mudanças climáticas, concentração urbana e novas tecnologias. Disponível em: https://drive.google.com/file/d/1NZgXgUmzTVBpJrXqKM76eFkpQ4nmzdkB/view. Acesso em: 11 out. 2023.pt_BR
dc.identifier.urihttp://repositorio2.unb.br/jspui/handle/10482/46662-
dc.description.abstractEste artigo apresenta o processo de adequação para etiqueta de eficiência energética nível “A” do projeto de três novas tipologias arquitetônicas para unidades de ensino fundamental com 5 e 9 salas, atualmente em desenvolvimento para as 8 zonas bioclimáticas brasileiras pela equipe técnica da Coordenação de Desenvolvimento de Infraestrutura (CODIN) do Fundo Nacional de Desenvolvimento da Educação (FNDE). O método está estruturado em 4 etapas: primeiramente, organizou-se um diagnóstico preliminar das etiquetas atuais dos projetos dos edifícios; na segunda etapa, atuou-se na adequação da transmitância térmica das paredes e cobertura, tendo sido calculados os respectivos resultados finais de etiqueta; a terceira etapa envolveu a simulação das horas ocupadas em conforto do Bloco de Sala de Aula; na quarta e última etapa foi apresentado um resumo das propostas de adequações por família de projeto. A análise foi feita por comparação entre dados de entrada (transmitância, fator solar do vidro, taxa de sombreamento) e resultados de etiqueta da envoltória, assim como entre os resultados de etiqueta e percentual de horas em conforto. Os dados mostraram que o alcance dos pré-requisitos com redução da transmitância térmica da envoltória foi suficiente para permitir etiqueta A em 6 das 8 zonas bioclimáticas brasileiras, com diferentes níveis de isolamento térmico da cobertura. Porém, foram necessárias estratégias adicionais para garantir o conforto térmico nas salas de aula. Neste sentido, concluiu-se que o projeto deveria sofrer alterações por grupos de zonas bioclimáticas, chegando a um total de 3 diferentes projetos-padrão.pt_BR
dc.language.isoporpt_BR
dc.publisherANTACpt_BR
dc.rightsAcesso Abertopt_BR
dc.titleAvaliação de eficiência energética e conforto térmico de projetos educacionais padronizados do FNDEpt_BR
dc.typeTrabalho apresentado em eventopt_BR
dc.subject.keywordEficiência energéticapt_BR
dc.subject.keywordEtiquetagempt_BR
dc.subject.keywordEscolas públicaspt_BR
dc.subject.keywordFundo Nacional de Desenvolvimento da Educação (Brasil)pt_BR
dc.subject.keywordConforto térmicopt_BR
dc.relation.publisherversionhttps://drive.google.com/file/d/1NZgXgUmzTVBpJrXqKM76eFkpQ4nmzdkB/viewpt_BR
dc.description.abstract1This article presents the adaptation process for label A of the project of three new architectural typologies for elementary schools with 5 and 9 rooms, currently under development for the 8 Brazilian bioclimatic zones by the technical team of the Coordination of Infrastructure Development – CODIN of the Education Development National Foundation FNDE. The methodological procedures of the article can be structured in 4 steps: the first one consisted of preliminary diagnosis of the current labels of the projects of the buildings; in the second step, the adequacy of the thermal transmittance of the walls and cover, and the respective final label results were calculated; the third step involved the simulation of the hours occupied in the comfort of the Classroom Block; in the fourth and last step, a summary of the proposals for adjustments by project family was presented. The analysis was comparing input data (transmittance, solar glass factor, shading rate) and envelope labelling results, as well as between label results and percent comfort hours. The data showed that the reach of the prerequisites with reduction of the thermal transmittance of the envelope was sufficient to allow A-label in 6 of the 8 Brazilian bioclimatic zones, with different levels of thermal insulation of the cover. However, additional strategies were required to ensure thermal comfort in classrooms. In this sense, it was concluded that the project should be modified by groups of bioclimatic zones, reaching a total of 3 different standard projects.pt_BR
dc.contributor.affiliationUniversidade de Brasília, Faculdade de Arquitetura e Urbanismo, Programa de Pós-Graduação em Arquitetura e Urbanismopt_BR
dc.contributor.affiliationUniversidade de Brasília, Faculdade de Arquitetura e Urbanismo, Programa de Pós-Graduação em Arquitetura e Urbanismopt_BR
dc.contributor.affiliationUniversidade de Brasília, Faculdade de Arquitetura e Urbanismo, Programa de Pós-Graduação em Arquitetura e Urbanismopt_BR
dc.contributor.affiliationQuali-A Conforto e Eficiência Energéticapt_BR
dc.contributor.affiliationUniversidade de Brasília, Faculdade de Arquitetura e Urbanismo, Programa de Pós-Graduação em Arquitetura e Urbanismopt_BR
dc.contributor.affiliationUniversidade de Brasília, Faculdade de Arquitetura e Urbanismo, Programa de Pós-Graduação em Arquitetura e Urbanismopt_BR
dc.description.unidadeFaculdade de Arquitetura e Urbanismo (FAU)pt_BR
dc.description.unidadeDepartamento de Tecnologia em Arquitetura e Urbanismo (FAU TEC)pt_BR
dc.description.ppgPrograma de Pós-Graduação em Arquitetura e Urbanismopt_BR
Aparece nas coleções:Trabalhos apresentados em evento