http://repositorio.unb.br/handle/10482/44715
Título: | Validity and intra-session reliability of a low-cost device for assessing isometric mid-thigh pull force |
Autor(es): | Couto, Diego Cunha, Rafael Lage, Victor Rocha Júnior, Valdinar de Araújo Santos, Wanderson Ferreia Júnior, João Tufano, James Vieira, Amilton |
ORCID: | https://orcid.org/0000-0003-1328-069X https://orcid.org/0000-0002-1865-2790 https://orcid.org/0000-0001-6322-9804 https://orcid.org/0000-0001-6973-6006 https://orcid.org/0000-0002-4378-1041 https://orcid.org/0000-0002-7541-8212 https://orcid.org/0000-0001-8325-0344 https://orcid.org/0000-0002-6027-4367 |
Assunto: | Aptidão muscular Força muscular Tração isométrica do meio da coxa (IMTP) |
Data de publicação: | 2022 |
Referência: | COUTO, Diego et al. Validity and intra-session reliability of a low-cost device for assessing isometric mid-thigh pull force. Human Movement, v. 24, n. 2, 2023. DOI 10.5114/hm.2023.115918. Disponível em: https://doi.org/10.5114/hm.2023.115918. Acesso em: 08 set. 2022. |
Abstract: | Purpose. The isometric mid-thigh pull (IMTP) test is a strength test usually requiring expensive equipment like a force platform. Low-cost alternatives could make IMTP testing more accessible. Previous research reported high systematic bias when comparing low-cost devices with more expensive criterion devices (force platforms). This study investigated the concurrent validity and intra-session reliability of a custom-built low-cost IMTP device using a load cell. Methods. Overall, 17 recreationally resistance-trained men (25 ± 6 years, 83 ± 14 kg, 178 ± 7 cm, 5 ± 3 years of resistance training experience) first visited the laboratory to be familiarized with testing protocols and returned 2–3 days later for IMTP testing with the low-cost device and a laboratory-grade force platform. Results. The overall bias was trivial (–0.8%, 95% CI: –5.7 to 4.3%). The typical error of the estimate was moderate (10.2%, 95% CI: 7.4–16.2%). A strong correlation of 0.91 (95% CI: 0.76–0.97) was found between peak force values from both devices; the low-cost IMTP device accounted for 81.3% of the variation in force platform. The low-cost IMTP also demonstrated acceptable scores for reliability and agreement (ICC = 0.96, 95% CI: 0.89–0.98; typical error = 5.0%, 95% CI: 3.7–7.7), similar to the criterion (ICC = 0.97, 95% CI: 0.91–0.99; typical error = 4.5%, 95% CI: 3.3–7.1). Conclusions. The low-cost IMTP device using a load cell was valid and reliable for maximal force production in recreationally trained men and provided results comparable with those of a force platform. |
Unidade Acadêmica: | Faculdade de Educação Física (FEF) |
DOI: | https://doi.org/10.5114/hm.2023.115918 |
Aparece nas coleções: | Artigos publicados em periódicos e afins |
Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.