Campo DC | Valor | Idioma |
dc.contributor.author | PADULA, NIURA A.M R. | pt_BR |
dc.contributor.author | RUGULO, LÍGIA M. SUPPO DE S. | pt_BR |
dc.contributor.author | PADOVANI, CARLOS ROBERTO | pt_BR |
dc.contributor.author | TEIXEIRA, ALTAMIR | pt_BR |
dc.contributor.author | FONSECA, RONALDO GUIMARÃES | pt_BR |
dc.contributor.author | MOURA-RIBEIRO, M. VALERIANA L. | pt_BR |
dc.contributor.author | MELO, ÁUREA NOGUEIRA DE | pt_BR |
dc.date.accessioned | 2017-12-07T04:28:49Z | - |
dc.date.available | 2017-12-07T04:28:49Z | - |
dc.date.issued | 1999 | pt_BR |
dc.identifier.citation | Arq. Neuro-Psiquiatr.,v.57,n.3A,p.571-579,1999 | pt_BR |
dc.identifier.uri | http://repositorio.unb.br/handle/10482/25481 | - |
dc.description.abstract | Analisamos o exame video-polissonográfico de 26 recém-nascidos de termo (RNT) com 24 horas de vida. Os RN tinham exame neurológico e ultrassonográfico cerebral normais e apresentaram período perinatal isento de complicações. Foram subdivididos em dois grupos, um controle constituído de 11 RNT com peso adequado para a idade gestacional; e um grupo de 15 RN com peso abaixo do esperado para o termo (RNT-PIG). Do segundo grupo, 13 RN apresentaram algum tipo de alteração ao exame video-polissonográfico. As alterações mais frequentes foram na arquitetura do sono, 11 casos, e no comportamento, em que oito RN apresentaram número excessivo de sobressaltos ("startle") em relação ao grupo controle e dois RN uma atividade motora reduzida. Os resultados deste estudo demonstram a utilidade da video-polissonografia quando aplicada a RNT-PIG. O exame mostrou-se sensível em detectar diferenças no comportamento, arquitetura do sono e padrão eletrencefalográfico dos RNT-PIG quando comparados ao grupo controle. | pt_BR |
dc.description.abstract | Video-polygraphic-EEG studies were performed in the first 24 life-hours of 26 healthy full-term newborns without perinatal injuries. The neurological examination and cranial ultrasonography were normal. The newborns were divided into two groups: one, with full-term appropriate - birth weight 11 newborns (control group ) and the other with full-term low-birth weight 15 newborns. Thirteen newborns of the second group had video-polygraphic-EEG study abnormalities. The most frequent abnormalities were found in 11 cases, as far as sleep architecture is concerned. Also, when compared with the control group, 8 cases of an excessive amount of startles and 2 cases of low behavior activities were found. The results demonstrate the usefulness of video-polygraphic-EEG study in the full-term newborns with intra-uterine growth retard. This examination was sensitive to detect behavior, sleep architecture and EEG standard differences in the low birth-weight newborns as to the control group. | pt_BR |
dc.language.iso | por | pt_BR |
dc.publisher | Academia Brasileira de Neurologia - ABNEURO | pt_BR |
dc.rights | Acesso Aberto | pt_BR |
dc.title | Estudo vídeo-polissonográfico em recém-nascidos de termo pequenos para a idade gestacional | pt_BR |
dc.title | Video-polygraphic-EEG study in the full-term newborn with low birthweight for their gestational age | pt_BR |
dc.type | Artigo | pt_BR |
dc.subject.keyword | Polissonografia neonatal | pt_BR |
dc.subject.keyword | RNT-PIG | pt_BR |
dc.subject.keyword | EEG neonatal | pt_BR |
dc.identifier.doi | https://dx.doi.org/10.1590/S0004-282X1999000400006 | pt_BR |
dc.description.unidade | Em processamento | - |
Aparece nas coleções: | Artigos publicados em periódicos e afins
|