Skip navigation
Use este identificador para citar ou linkar para este item: http://repositorio.unb.br/handle/10482/14687
Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
2013_CarolinaGirardiAlves.pdf14,99 MBAdobe PDFVisualizar/Abrir
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.advisorMarães, Vera Regina Fernandes da Silva-
dc.contributor.authorAlves, Carolina Girardi-
dc.date.accessioned2013-11-25T11:18:24Z-
dc.date.available2013-11-25T11:18:24Z-
dc.date.issued2013-11-25-
dc.date.submitted2013-07-23-
dc.identifier.citationALVES, Carolina Girardi. Avaliação eletromiográfica de amputados transfemorais para ativação de membros artificiais. 2013. xv, 197 f., il. Dissertação (Mestrado em Engenharia Biomédica)—Universidade de Brasília, Brasília, 2013.en
dc.identifier.urihttp://repositorio.unb.br/handle/10482/14687-
dc.descriptionDissertação (mestrado)—Universidade de Brasília, Faculdade Gama, Programa de Pós-Graduação em Engenharia Biomédica, 2013.en
dc.description.abstractA amputação transfemoral gera uma série de mudanças nas funções biomecânicas no corpo do indivíduo e que podem interferir no dia a dia do amputado. Tais mudanças podem gerar padrões de postura e de marcha diferentes, a fim de se adaptarem à perda do membro. O presente estudo tem como objetivo avaliar a viabilidade eletromiográfica de diferentes músculos do quadril em indivíduos amputados transfemorais unilaterais de membro inferior correlacionando os achados em indivíduos normais para o controle de um membro artificial desenvolvido pelo laboratório de automação e robótica da Universidade de Brasília. Os voluntários foram divididos em dois grupos: oito amputados, os quais são do sexo masculino e fisicamente ativos e um grupo controle composto por oito indivíduos do sexo masculino, não amputados e não sedentários. Os músculos do quadril foram avaliados de acordo com o consenso geral de colocação de eletrodos preconizado pelo projeto europeu SENIAM. Foram selecionados músculos da perna sadia e do coto residual, sendo eles: reto femoral (RF), semitendinoso (ST), além de musculaturas paravertebrais e bíceps femoral (BF). Dessa forma, foram analisados músculos esqueléticos agonistas e antagonistas durante a contração isométrica nos movimentos de flexão e extensão do quadril os quais foram controlados por uma cadeira isocinética e depois durante o ciclo de marcha, na esteira. Assim foi possível determinar um padrão de amplitude (RMS) e frequência mediana (Fmed) dos sinais eletromiográficos para os amputados e também possibilitou a mensuração do pico médio de torque (PMT) desses músculos para futuras análises no controle membros artificiais. __________________________________________________________________________________ ABSTRACTen
dc.description.abstractThe transfemoral amputation leads to a series of changes in functional biomechanics body that can interfere with daily life of the amputee can generate patterns of posture and gait to compensate for the loss of the limb. This study aims assessing the eletectromyographic feasibility of different hip muscles on transfemoral unilateral lower limb amputees in control of artificial limbs, which were developed by the laboratory of electrical engineering and robotics at the University of Brasilia. The volunteers will be split into two groups: eight male, physically active amputees and a control group who are also eight male, healthy, but they are non-amputees individuals. The hip muscles will be assessed in accordance with the general consensus of the placing of electrodes established by the European project SENIAM. Healthy leg muscles were selected and they are: retus femoralis (RF), semitendineous (ST), in addition to paravertebral muscles and bíceps femoralis (BF). In this way, agonists and antagonists skeleton muscles were evaluated during the isometric contraction of hip’s movements of extension and flexion, which were controlled by an isokinect chair and them during gait on a treadmill. So, it was possible to assess a pattern of electromyographic signals in amplitude (RMS) and median frequency (Fmed) of the amputees and it were also possible to measure the mean torque pikes (PMT) of these skeleton muscles to future assessments on artificial limbs control.en
dc.language.isoPortuguêsen
dc.rightsAcesso Abertoen
dc.titleAvaliação eletromiográfica de amputados transfemorais para ativação de membros artificiaisen
dc.title.alternativeElectromyographyc assessment in transfemoral amputees to enable artificial limbsen
dc.typeDissertaçãoen
dc.subject.keywordMúsculosen
dc.subject.keywordEletromiografiaen
dc.rights.licenseA concessão da licença deste item refere-se ao termo de autorização impresso assinado pelo autor com as seguintes condições: Na qualidade de titular dos direitos de autor da publicação, autorizo a Universidade de Brasília e o IBICT a disponibilizar por meio dos sites www.bce.unb.br, www.ibict.br, http://hercules.vtls.com/cgi-bin/ndltd/chameleon?lng=pt&skin=ndltd sem ressarcimento dos direitos autorais, de acordo com a Lei nº 9610/98, o texto integral da obra disponibilizada, conforme permissões assinaladas, para fins de leitura, impressão e/ou download, a título de divulgação da produção científica brasileira, a partir desta data.en
dc.contributor.advisorcoRodrigues, Araken dos Santos Werneck-
dc.description.unidadeFaculdade UnB Gama (FGA)pt_BR
dc.description.ppgPrograma de Pós-Graduação em Engenharia Biomédicapt_BR
Aparece nas coleções:Teses, dissertações e produtos pós-doutorado

Mostrar registro simples do item Visualizar estatísticas



Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.