Skip navigation
Use este identificador para citar ou linkar para este item: http://repositorio2.unb.br/jspui/handle/10482/14178
Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
ARTIGO_UseDiagnodentDiagnosis.pdf72,62 kBAdobe PDFVisualizar/Abrir
Título: Use of diagnodent® for diagnosis of non-cavitated occlusal dentin caries
Autor(es): Costa, Ana Maria
Paula, Lilian Marly de
Bezerra, Ana Cristina Barreto
Assunto: Cáries dentárias
Cáries dentárias em crianças
Dentes - doenças
Cáries dentárias - prevenção
Lasers em odontologia
Data de publicação: Jan-2008
Editora: Faculdade de Odontologia de Bauru - USP
Referência: COSTA, Ana Maria; PAULA, Lilian Marly de; BEZERRA, Ana Cristina Barreto. Use of diagnodent® for diagnosis of non-cavitated occlusal dentin caries. Journal of Applied Oral Science, Bauru, v. 16, n. 1, jan./fev. 2008. Disponível em: <http://www.scielo.br/scielo.php?script=sci_abstract&pid=S1678-77572008000100005&lng=en&nrm=iso&tlng=en>. Acesso em: 20 set. 2013. DOI: http://dx.doi.org/10.1590/S1678-77572008000100005.
Resumo: The purpose of this study was to evaluate the use of a laser fluorescence device for detection of occlusal caries in permanent teeth. One hundred and ninety-nine non-cavitated teeth from 26 patients aged 10 to 13 years were selected. After dental prophylaxis, two previously calibrated dentists examined the teeth. Visual inspection, radiographic examination and laser measurements were performed under standardized conditions. The validation method was cavity preparation with a small cone-shaped diamond bur, when the two examiners agreed about the presence of dentin caries. It was found that the laser detection method produced high values of sensitivity (0.93) and specificity (0.75) and a moderate positive predictive value (0.63). The laser device showed the lowest value of likelihood ratio (3.68). Kappa coefficient showed good repeatability for all methods. Although the laser device had an acceptable performance, this equipment should be used as an adjunct method to visual inspection to avoid false positive results.
Licença: Journal of Applied Oral Science - Todo o conteúdo do periódico, exceto onde está identificado, está licenciado sob uma Licença Creative Commons - Attribution-NonCommercial 3.0 Unported (CC BY-NC 3.0). Fonte: http://www.scielo.br/scielo.php?script=sci_serial&pid=1678-7757&lng=pt&nrm=iso. Acesso em: 20 set. 2013.
DOI: http://dx.doi.org/10.1590/S1678-77572008000100005
Aparece nas coleções:Artigos publicados em periódicos e afins

Mostrar registro completo do item Visualizar estatísticas



Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.